McNaughton-McKay offers electrical hardware, controls & software. We are proud to represent the industries best-known quality manufacturers. Allen-bradley PowerFlex 20-750-UFB-1 Pdf User Manuals. View online or download Allen-bradley PowerFlex 20-750-UFB-1 Installation Instructions Manual. (1) For detailed instructions on installation of 11-Series I/O with the ATEX option module, refer to the PowerFlex 750-Series ATEX User Manual, p ublication 750-UM003 (2) See Using 20-750-S1 with 20-750-DENC-1. Allen-Bradley PowerFlex 20-750-UFB-1 Manuals & User Guides. User Manuals, Guides and Specifications for your Allen-Bradley PowerFlex 20-750-UFB-1 Controller. Database contains 1 Allen-Bradley PowerFlex 20-750-UFB-1 Manuals (available for free online viewing or downloading in PDF): Installation instructions manual.
These instructions cover the installation of the option modules listed below. For instructions on installing Network Communication option modules, refer to publication
750COM-IN002
.
Compatible Ports
Option Module Installation
Using 20-750-S1 with 20-750-DENC-1
20-750-APS
20-750-S
20-750-ufb-1 Manual
20-750-S1
20-750-2262C-2R
20-750-2263C-1R2T
20-750-2262D-2R
20-750-1132C-2R
20-750-1133C-1R2T
20-750-1132D-2R
20-750-ENC-1
20-750-DENC-1
20-750-UFB-1
20-750-ATEX
Option Module Cat. No. 20-750-
PowerFlex 753 Drives
PowerFlex 755 Drives
Frame 1 Ports
Frame 2…7 Ports
Frame 1 Ports
Frame 2…10 Ports
APS
See Page 2
See Page 2
See Page 2
Yes
No
No
No
No
2262C-2R, 2263C-1R2T, 2262D-2R
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1132C-2R, 1133C-1R2T, 1132D-2R
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1132C-2R, 1133C-1R2T, 1132D-2R with 20-750-ATEX installed
(1)
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
No
No
Yes
Yes
ENC-1
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
UFB-1
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
Yes
Yes
Yes
S
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
S1
(2)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
DENC-1
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(1) For detailed instructions on installation of 11-Series I/O with the ATEX option module, refer to the PowerFlex 750-Series ATEX User Manual, publication
750-UM003
.
(2) See Using 20-750-S1 with 20-750-DENC-1.
0.45 N•m (4.0 lb•in)
20-750-S1
20-750-DENC-1
IMPORTANT: When a Safe Speed Monitor option (20-750-S1) is used with a Dual Incremental Encoder option (20-750-DENC-1) both modules must be installed on the same backplane (ports 6, 5, 4).
IMPORTANT: Only one safety option module can be installed at a time. Multiple safety options or duplicate safety option installations are not supported.